When simulation and measurement disagree, first align operating conditions and the quantity being compared. Check probe and instrument effects as well as model simplifications, and test one change at a time.
Contents
- A comparison record for simulation and measurement
- First, check whether you are comparing the “same amount”
- Align operating conditions in one comparison table
- What is included in the model and what is not included?
- Inspect not only the actual machine but also the measurement system
- Narrow down the hypotheses to confirm based on the appearance of differences
- Returning correlation to design decisions
- Information to gather before consultation
- Summary: Make comparisons that explain the differences
- Technical support information
- Related Articles
- Discuss your project
A circuit that had no problems in analysis generates heat in actual equipment. The waveform on the model and the measured waveform are different. When such a difference occurs at the development site, it is tempting to first determine whether the model is incorrect or the actual machine is poorly designed. However, there may be differences in the conditions and measurement methods being compared.
In order to match the analysis and actual device evaluation, it is necessary to be able to explain the cause of the difference, rather than just making the numbers the same. In this article, we will introduce how to proceed by checking the comparison target, operating conditions, model range, and measurement system in that order, and then returning the results to the next design decision.
A comparison record for simulation and measurement
| Item | What to check | How to assess it |
|---|---|---|
| Quantity | Peak, mean, RMS and time window | Align units and processing |
| Conditions | Input, load, temperature and control | Record actual as well as commanded values |
| Measurement | Bandwidth, connection, calibration and timing | Retain raw data and settings |
First, check whether you are comparing the “same amount”
Even though the expression "current" is the same, instantaneous value, average value, effective value, and peak value have different meanings. For the output of the analysis software and the display of the measuring instrument, align the values calculated for what time range. For voltage, temperature, loss, and efficiency, we also clarify the locations where they are being evaluated and the aggregation methods.
For example, the validity of the model cannot be determined by comparing the maximum current at startup with the average current after stable operation. Temperature is also an estimated value inside the part, measured value on the surface, and ambient temperature are different quantities. By showing the measurement points and the corresponding points on the model in a diagram, you can confirm that you are not comparing different things.
Before overlapping the graphs, list the units, time axis, reference point, and target interval. If you use averaging or filtering in data processing, leave those conditions as well. By arranging the comparison conditions first, you can distinguish between apparent differences and differences that should be investigated in terms of design.
We will also arrange the expression of differences. If you only look at the ratio to the standard value, the difference may appear large in areas where the standard value is small. Looking at absolute value differences, trends of change, and time response differences together helps explain the differences in relation to design decisions. Pass/fail conditions also correspond to which quantities and ranges are being evaluated.
Align operating conditions in one comparison table
Check whether the input voltage, load, rotation speed, control conditions, and temperature specified in the analysis match the actual machine test. Record not only the command value but also the value that actually occurred during the test. Conditions external to the target equipment are also compared, including power supplies, wiring, loads, and cooling methods.
| Comparison items | Information left on the analysis side | Information left on the actual device |
|---|---|---|
| Input/load | Setting value, timing of change | Actual measurements, power supply and load conditions |
| control | Control method, parameters | Software version, settings, and operating status |
| Temperature/cooling | Initial temperature, boundary conditions | Ambient temperature, cooling conditions, measurement position |
| amount to evaluate | Output point, calculation interval, processing method | Measurement points, equipment settings, processing methods |
If an item that does not match is found, a test with the same conditions is performed first. If you change the model, control, and cooling all at once, you won't know why even if the difference becomes smaller. Record changes made in the comparison table so you can track which changes affected the results.
Also check the elapsed time since the start of the exam. Comparing the results in a cold state and the results after continued operation includes differences in temperature conditions. Measure multiple times with the same settings to see if the results are reproducible, and then examine the differences in conditions. If it does not reproduce, check the stability of the test configuration and recordings before modifying the model.
What is included in the model and what is not included?
A model is a simplified version of an actual machine depending on the phenomenon you want to investigate. The required level of detail is different between a model for method comparison and a model for examining switching waveforms and local temperatures. Confirm the purpose for which the model was created, and review whether the structure can express the current evaluation items.
Actual equipment has characteristics that vary due to wiring, mounting, component variations, and temperature. You don't have to add all the elements at once when you see a difference. Based on the conditions under which the phenomenon occurs and the characteristics of the waveform, list the factors that are likely to have an influence, and decide the order in which to check each hypothesis.
Don't stop just by meeting one condition
Even if a parameter is adjusted to match the measured value at one load, it may not necessarily be explained in the same way at other loads or temperatures. Separate the conditions used for adjustment and other conditions used for confirmation. Make sure there is a physical basis for the changed parameters, and avoid increasing corrections just to make the values match.
Inspect not only the actual machine but also the measurement system
Instruments, probes, and connection methods also affect measurement results. Check the probe type, band, measurement range, sampling, trigger, calibration and settings. When calculating loss etc. from voltage and current, it is necessary to align the time relationships of the acquired signals and the sections to be evaluated.
Tektronix documentation explains how probe connections and loading can affect the signal, and that long ground leads can contribute to waveform ringing. Rather than assuming that all vibrations in the measured waveform are a phenomenon of the actual machine, check whether it can be reproduced with an appropriate measurement configuration. Reference: How Oscilloscope Probes Affect Your Measurement, ABCs of Probes Primer.
When measuring high voltages or circuits that are not referenced to ground potential, check in advance the measurement method, such as the rating of the measuring instrument and probe, the grounding method, and the appropriate differential probe for the target. Do not take measurements by removing the protective ground of the grounded oscilloscope or by connecting the ground lead of a typical probe to an ungrounded point. When changing connections, check the potential and stored energy of the target circuit, and follow the instruction manual and safety procedures for the equipment being used. Reference: Floating Oscilloscope Measurements ... And Operator Protection.
If you change the measurement location, use a different instrument, or change cables, record the difference. The conditions cannot be reproduced simply by using the same file name as the previous exam. If you save a photo of the test configuration, wiring diagram, settings, and raw data as a set, it will be easier to investigate the cause later.
Narrow down the hypotheses to confirm based on the appearance of differences
We break down "doesn't match" into what conditions, what amounts, and how they differ. Is the steady value different? Is the difference only during startup? Does the difference increase as the temperature rises? Or is the difference only in a specific section of the waveform? Once the differences are aligned, the purpose of the additional test becomes clear.
For example, if the actual load is different even though the command value is the same, first match the load conditions. If the difference remains even after adjusting the conditions, check the range of the measurement system and model. By first writing down the hypothesis, one item to be changed, and the expected result, and then comparing the data before and after the change, we can gradually reduce the number of possible causes.
Even if we cannot identify the cause, we will report the confirmed hypothesis and the remaining hypotheses separately. Not only the result that the difference has become smaller, but also the range that can be explained, the conditions that have been reproduced, and the conditions that have not been reproduced can be used as judgment materials for the next design.
For example, if the temperature difference increases only when the load is increased, match the actual measurement conditions of each load with the loss/cooling model. If we conduct a separate test to change the cooling conditions and an analysis to review the component characteristics, we can examine which one is related to the difference. This example is an idea of isolation and does not conclude the specific cause.
Returning correlation to design decisions
Once the correlation between the analysis and the actual machine has been established, it is necessary to determine what decisions the model will be used for. Determine the evaluation amount and allowable difference depending on the purpose, such as method comparison, component selection, control adjustment, thermal design, etc. It is important not to assume that predictions can be made with the same accuracy outside the operating range that we confirmed this time.
The models, circuit diagrams, software, and test conditions versions are matched and left in a format that allows the next person in charge to trace the evidence. By going back and forth between updating the model and evaluating the actual machine in short cycles, analysis does not become a separate task from the design, and what is learned from prototyping can be reflected in the next design.
The documents to be carried over will summarize the results of this comparison, the hypotheses adopted, changes, and unconfirmed conditions. If you leave not only the waveform image but also the raw data and processing method, you can check it when investigating other evaluation quantities. Boundaries are important for determining whether the model can be used as is if conditions change in the next process.
Information to gather before consultation
- Definition of physical quantities being compared, measurement points, units, averages/peaks, etc.
- Analysis model and parameters, target version of actual circuit/software
- Power, load, temperature, cooling, instrumentation and connection conditions
- Conditions that matched, conditions that caused a difference, raw data and change history
Summary: Make comparisons that explain the differences
If the analysis and actual equipment evaluation do not match, prepare the quantities and conditions for comparison and check both the model and measurement system. By testing each hypothesis and clarifying its applicable range, you can go beyond simply matching numbers and leave a model and evaluation results that can be used for design.
Technical support information
At LinkT&B, you can consult with us about electrical/thermal/control analysis, circuit/embedded design, prototype production/actual equipment evaluation. For more information, please see R&D/Power Electronics Business, and for individual consultation, please see Contact Us.
Related Articles
Starting a Development Project Without a Specification
Why a Working Prototype Can Stall Before Production
Discuss your project
We support circuit design, prototyping and hardware testing. Tell us about the operating conditions and the problem you need to investigate.